SMART Health Cards: Terminology
0.1.0 - ci-build

SMART Health Cards: Terminology - Local Development build (v0.1.0). See the Directory of published versions

ValueSet: Qualitative infectious disease-related lab test result codes

Official URL: https://terminology.smarthealth.cards/ValueSet/lab-qualitative-result Version: 2022.2
Draft as of 2023-07-06 Computable Name: LabQualitativeResultValueSet

Copyright/Legal: This material contains content from LOINC (http://loinc.org). LOINC is copyright © 1995-2022, Regenstrief Institute, Inc. and the Logical Observation Identifiers Names and Codes (LOINC) Committee and is available at no cost under the license at http://loinc.org/license. LOINC® is a registered United States trademark of Regenstrief Institute, Inc

The SNOMED CT codes in this ValueSet are part of SNOMED GPS, which is produced by SNOMED International under the terms of the Creative Commons Attribution 4.0 International Public License.

Additional information about this license specific to SNOMED International’s release of the GPS:

  • SNOMED CT is © and ® SNOMED International. The right to maintain the GPS remains vested exclusively in SNOMED International.
  • The Licensee can redistribute the GPS.
  • The Licensee can create derivatives or implementation-related products and services based on the GPS.
  • The Licensee cannot claim that SNOMED International or any of its Members endorses the Licensee’s derivative because it uses content from the GPS.
  • Neither SNOMED International nor any of the contributors accept any liability for the Licensee’s use or redistribution of the GPS.
  • SNOMED CT® was originally created by the College of American Pathologists.

Without obtaining prior written permission from SNOMED International, you are expressly prohibited from using, distributing or reproducing the SNOMED International, SNOMED CT or SNOMED GPS logo, service mark or trademark. Please review all terms and conditions of use here.

This value set includes a codes to identify the results of qualitative lab tests related to infectious diseases.

References

This value set is not used here; it may be used elsewhere (e.g. specifications and/or implementations that use this content)

Usage

Use of SNOMED CT concepts for representing laboratory test results is preferred. For convenience, the table below provides equivalencies between SNOMED CT concepts and LOINC answers.

SNOMED-CT LOINC Answer
260415000
Not detected (qualifier value)
LA11883-8
Not detected
260373001
Detected (qualifier value)
LA11882-0
Detected
419984006
Inconclusive (qualifier value)
LA9663-1
Inconclusive
42425007
Equivocal (qualifier value)
LA11885-3
Equivocal
10828004
Positive (qualifier value)
LA6576-8
Positive
260385009
Negative (qualifier value)
LA6577-6
Negative
82334004
Indeterminate (qualifier value)
LA11884-6
Indeterminate
11214006
Reactive (qualifier value)
LA15255-5
Reactive
131194007
Non-reactive (qualifier value)
LA15256-3
Nonreactive
720735008
Presumptive positive (qualifier value)
LA31317-3
Presumptive positive
415684004
Suspected (qualifier value)
LA15291-0
Suspected
125154007
Specimen unsatisfactory for evaluation (finding)
LA13548-5
Specimen unsatisfactory for evaluation
455371000124106
Invalid result (qualifier value)
LA15841-2
Invalid
419984006
Inconclusive (qualifier value)
LA4259-3
Borderline
260415000
Not detected (qualifier value)
LA28480-4
Ab not detected
No equivalent LA28481-2
Past infection
No equivalent LA28482-0
Recent infection
407479009
Influenza A virus (organism)
LA11919-0
Influenza A virus
407480007
Influenza B virus (organism)
LA13543-6
Influenza B virus
840533007
Severe acute respiratory syndrome coronavirus 2 (organism)
LA31065-8
SARS coronavirus 2

This ValueSet is programmatically generated by this script.

Logical Definition (CLD)

The following codes from the Logical Observation Identifiers, Names and Codes (LOINC) code system are included:

Code Description(s)
LA28481-2 Past infection
LA28482-0 Recent infection

The following codes from the SNOMED CT (all versions) code system are included:

Code Description(s)
10828004 Positive (qualifier value)
11214006 Reactive (qualifier value)
125154007 Specimen unsatisfactory for evaluation (finding)
131194007 Non-reactive (qualifier value)
260373001 Detected (qualifier value)
260385009 Negative (qualifier value)
260415000 Not detected (qualifier value)
407479009 Influenza A virus (organism)
407480007 Influenza B virus (organism)
415684004 Suspected (qualifier value)
419984006 Inconclusive (qualifier value)
42425007 Equivocal (qualifier value)
455371000124106 Invalid result (qualifier value)
720735008 Presumptive positive (qualifier value)
82334004 Indeterminate (qualifier value)
840533007 Severe acute respiratory syndrome coronavirus 2 (organism)

 

Expansion

No Expansion for this valueset (not supported by Publication Tooling)


Explanation of the columns that may appear on this page:

Level A few code lists that FHIR defines are hierarchical - each code is assigned a level. In this scheme, some codes are under other codes, and imply that the code they are under also applies
System The source of the definition of the code (when the value set draws in codes defined elsewhere)
Code The code (used as the code in the resource instance)
Display The display (used in the display element of a Coding). If there is no display, implementers should not simply display the code, but map the concept into their application
Definition An explanation of the meaning of the concept
Comments Additional notes about how to use the code