SMART Health Cards: Terminology
0.1.0
- ci-build
SMART Health Cards: Terminology - Local Development build (v0.1.0). See the Directory of published versions
Official URL: https://terminology.smarthealth.cards/ValueSet/qualitative-lab-test-result-value-set | Version: 0.1.0 | |||
Active as of 2022-09-15 | Responsible: VCI | Computable Name: QualitativeLabTestResultValueSet | ||
Copyright/Legal: This material contains content from LOINC (http://loinc.org). LOINC is copyright © 1995-2022, Regenstrief Institute, Inc. and the Logical Observation Identifiers Names and Codes (LOINC) Committee and is available at no cost under the license at http://loinc.org/license. LOINC® is a registered United States trademark of Regenstrief Institute, Inc The SNOMED CT codes in this ValueSet are made available by SNOMED International to users at no cost, and are licensed under the Creative Commons Attribution 4.0 International License. |
This value set includes a codes to identify the results of qualitative lab tests related to infectious diseases.
References
This value set is not used here; it may be used elsewhere (e.g. specifications and/or implementations that use this content)
Whenever possible, SNOMED CT codes SHALL be be used. If no equivalent code is available, LOINCs MAY be used as a fallback.
A concept map is forthcoming. Until then, here is a human-readable crosswalk between the relevant SNOEMD CT codes and LOINCs:
SNOMED-CT | LOINC Answer |
---|---|
260415000 Not detected (qualifier value) |
LA11883-8 Not detected |
260373001 Detected (qualifier value) |
LA11882-0 Detected |
419984006 Inconclusive (qualifier value) |
LA9663-1 Inconclusive |
42425007 Equivocal (qualifier value) |
LA11885-3 Equivocal |
10828004 Positive (qualifier value) |
LA6576-8 Positive |
260385009 Negative (qualifier value) |
LA6577-6 Negative |
82334004 Indeterminate (qualifier value) |
LA11884-6 Indeterminate |
11214006 Reactive (qualifier value) |
LA15255-5 Reactive |
131194007 Non-reactive (qualifier value) |
LA15256-3 Nonreactive |
720735008 Presumptive positive (qualifier value) |
LA31317-3 Presumptive positive |
415684004 Suspected (qualifier value) |
LA15291-0 Suspected |
125154007 Specimen unsatisfactory for evaluation (finding) |
LA13548-5 Specimen unsatisfactory for evaluation |
455371000124106 Invalid result (qualifier value) |
LA15841-2 Invalid |
No equivalent | LA4259-3 Borderline |
No equivalent | LA28480-4 Ab not detected |
No equivalent | LA28481-2 Past infection |
No equivalent | LA28482-0 Recent infection |
407479009 Influenza A virus (organism) |
LA11919-0 Influenza A virus |
407480007 Influenza B virus (organism) |
LA13543-6 Influenza B virus |
840533007 Severe acute respiratory syndrome coronavirus 2 (organism) |
LA31065-8 SARS coronavirus 2 |
This ValueSet is programmatically generated by this script.
Exception generating Narrative: unexpected non-end of element null::a at line 3 column 74
Explanation of the columns that may appear on this page:
Level | A few code lists that FHIR defines are hierarchical - each code is assigned a level. In this scheme, some codes are under other codes, and imply that the code they are under also applies |
System | The source of the definition of the code (when the value set draws in codes defined elsewhere) |
Code | The code (used as the code in the resource instance) |
Display | The display (used in the display element of a Coding). If there is no display, implementers should not simply display the code, but map the concept into their application |
Definition | An explanation of the meaning of the concept |
Comments | Additional notes about how to use the code |