SMART Health Cards: Terminology
0.1.0 - ci-build

SMART Health Cards: Terminology - Local Development build (v0.1.0). See the Directory of published versions

ValueSet: Qualitative infectious disease-related lab test result codes

Official URL: https://terminology.smarthealth.cards/ValueSet/qualitative-lab-test-result-value-set Version: 0.1.0
Active as of 2022-09-15 Responsible: VCI Computable Name: QualitativeLabTestResultValueSet

Copyright/Legal: This material contains content from LOINC (http://loinc.org). LOINC is copyright © 1995-2022, Regenstrief Institute, Inc. and the Logical Observation Identifiers Names and Codes (LOINC) Committee and is available at no cost under the license at http://loinc.org/license. LOINC® is a registered United States trademark of Regenstrief Institute, Inc

The SNOMED CT codes in this ValueSet are made available by SNOMED International to users at no cost, and are licensed under the Creative Commons Attribution 4.0 International License.

This value set includes a codes to identify the results of qualitative lab tests related to infectious diseases.

References

This value set is not used here; it may be used elsewhere (e.g. specifications and/or implementations that use this content)

Usage

Whenever possible, SNOMED CT codes SHALL be be used. If no equivalent code is available, LOINCs MAY be used as a fallback.

A concept map is forthcoming. Until then, here is a human-readable crosswalk between the relevant SNOEMD CT codes and LOINCs:

SNOMED-CT LOINC Answer
260415000
Not detected (qualifier value)
LA11883-8
Not detected
260373001
Detected (qualifier value)
LA11882-0
Detected
419984006
Inconclusive (qualifier value)
LA9663-1
Inconclusive
42425007
Equivocal (qualifier value)
LA11885-3
Equivocal
10828004
Positive (qualifier value)
LA6576-8
Positive
260385009
Negative (qualifier value)
LA6577-6
Negative
82334004
Indeterminate (qualifier value)
LA11884-6
Indeterminate
11214006
Reactive (qualifier value)
LA15255-5
Reactive
131194007
Non-reactive (qualifier value)
LA15256-3
Nonreactive
720735008
Presumptive positive (qualifier value)
LA31317-3
Presumptive positive
415684004
Suspected (qualifier value)
LA15291-0
Suspected
125154007
Specimen unsatisfactory for evaluation (finding)
LA13548-5
Specimen unsatisfactory for evaluation
455371000124106
Invalid result (qualifier value)
LA15841-2
Invalid
No equivalent LA4259-3
Borderline
No equivalent LA28480-4
Ab not detected
No equivalent LA28481-2
Past infection
No equivalent LA28482-0
Recent infection
407479009
Influenza A virus (organism)
LA11919-0
Influenza A virus
407480007
Influenza B virus (organism)
LA13543-6
Influenza B virus
840533007
Severe acute respiratory syndrome coronavirus 2 (organism)
LA31065-8
SARS coronavirus 2

This ValueSet is programmatically generated by this script.

Logical Definition (CLD)

Exception generating Narrative: unexpected non-end of element null::a at line 3 column 74

 

Expansion


Explanation of the columns that may appear on this page:

Level A few code lists that FHIR defines are hierarchical - each code is assigned a level. In this scheme, some codes are under other codes, and imply that the code they are under also applies
System The source of the definition of the code (when the value set draws in codes defined elsewhere)
Code The code (used as the code in the resource instance)
Display The display (used in the display element of a Coding). If there is no display, implementers should not simply display the code, but map the concept into their application
Definition An explanation of the meaning of the concept
Comments Additional notes about how to use the code